SHIMADZU LC AUTOSAMPLERS
|
|
|
These autosamplers depend on the use of screw top vials.
They also rely on the use of a white or yellow plastic to
allow the vial detection system to operate correctly. Shimadzu’s
SIL-10Axi works best with a pre-cut seal such as our 8-ST14X.
For the rest of the range our PTFE discs or our ST-101 seals
are recommended. Some later versions of the Shimadzu autosampler
are compatible with our WebSeal™ products.
|
|
|
| Table
1 |
VIALS
USING 11mm CRIMP CAPS |
| |
2-SV |
2mL,
clear glass, flat bottom, screw top vial. With 'write-on' patch. |
| |
2-SVG
|
2mL,
clear glass, flat bottom, screw top vial. Made from inert CHROMACOL
GOLD
grade glass. |
| 2a |
2-SV(A)
|
2mL,
amber glass, flat bottom screw top vial. With 'write-on' patch. |
| |
1.1-STVG |
1.1mL,
clear glass, screw top, tapered vial made from inert CHROMACOL
GOLD grade glass. Needs a TTS-312 PTFE support sleeve
when not suspend from cap |
| |
06-PESV |
600µL,
polyethylene screw top vial with an internal tapered profile. |
| |
06-PPSV |
600µL,
polypropylene screw top vial with an internal tapered profile. |
| |
RECOMMENDED
CAPS |
| |
8-SCJ(W) |
White
screw cap, no seal. Has wider flange suitable for Japanese autosamplers
wich suspend the vial by the cap. The 8-SCJ(Y) yellow may also
be used. |
| |
RECOMMENDED
SEALS |
| |
8-ST101 |
1mm
thick blue silicone/PTFE seal. Shore hardness value 30. |
| |
8-ST143 |
1.4mm
thick white silicone/whitePTFE seal. Shore hardness value 20.
|
| |
8-ST14X |
1.4mm
thick blue silicone/PTFE seal. Pre-cut |
| |
8-T02 |
0.25mm
thick, white PTFE disc type seal. Not resealable |
|
| Table
2 |
VIALS USING
12mm SCREW CAPS
Rack
L (Green)
|
| 3a |
4-SV |
4mL,
clear glass, screw top, flat bottom vial. |
| 3 |
4-SV(A) |
4mL,
amber glass, screw top, flat bottom vial. |
| |
RECOMMENDED CAPS |
| |
12-SC(W) |
White
screw cap, no seal. |
| |
12-SC(Y) |
Yellow
screw cap, no seal. |
| |
RECOMMENDED
SEALS |
| |
12-ST101 |
1mm
thick blue silicone/PTFE. Shore hardness value 20. Good for
ECD |
| |
12-ST143 |
1mm
thick white silicone/PTFE. Shore hardness value 30. |
| |
12-T02 |
0.25mm
thick white PTFE seal. |
|
| Table
3 |
MICRO-VIALS
USING 8MM CRIMP CAPS |
| |
03-CVG |
300µL,
clear glass, crimp top, round bottom vial, made from inert CHROMACOL
GOLD
grade glass. |
| 4a |
02-CTVG |
200µL,
clear glass, crimp top, tapered vial, made from inert CHROMACOL
GOLD
grade glass. |
| |
01-CVG |
100µL,
clear glass, crimp top, round bottom vial, wit needle guide,
made from inert CHROMACOL GOLD grade glass.
The above 3 vials use the SV-S12A support. |
| Table
3 |
RECOMMENDED
8mm CRIMP (Silver) CAPS |
| |
8-AC7 |
Aluminium
crimp cap fitted with a type 7, rubber/PTFE seal. Shore hardness
value 60. |
| |
8-AC-ST101 |
Aluminium
crimp cap fitted with a blue silicone/PTFE seal. Shore hardness
value 30. Good for ECD |
| |
8-AC-ST101X |
Aluminium
crimp cap fitted with a pre-cut blue silicone/PTFE seal. |
| |
8-ACT |
Aluminium
crimp cap fitted with a plain PTFE disc seal. Does not re-seal. |
| |
8-PECIX |
Polyethylene
SNAP CAP
pre-cut. |
|
| Table
4 |
LOW
VOLUME INSERTS FOR USE WITH 2-SV, 2-SV(A), 2-SVG |
| |
2-MTV
|
200µL,
clear glass, tapered low volume insert. Needs MTS-1 support. |
| |
2-NV |
200µL,
clear glass, low volume, flat bottom insert. No support needed. |
|
| Note |
SIL-10AXi